1. Home
  2. Converters
  3. Tons of Refrigeration to BTU/h

Tons of Refrigeration to BTU/h

For homeowners and technicians sizing air conditioning.

Free, no sign-up. Runs in your browser: nothing is uploaded.

Free workspace included. Docs, spreadsheets, notes and tasks that save on your device. No sign-up.Take a look

How to use Tons of Refrigeration to BTU/h

  1. Type a value and check the two units.
  2. Read the result, the formula and the table.
  3. Copy the number, or swap the direction.

Features

  • TR, BTU/h, kW, W, hp
  • Table 0.5 to 20 tons
  • Cooling kW shown
  • Swap direction
  • 1 TR = 12,000 BTU/h

Supported formats

Input

  • A typed number

You get

  • On-screen result
  • Copyable number
  • Reference table

Private by design

Everything you enter is processed by your browser on this device. Nothing is sent to openWorkstand or anyone else, so the Tons of Refrigeration to BTU/h is safe for private and work data. After you have used it once while online, it also works without an internet connection. How local processing works

Good to know

  • It converts the unit and does not size an air conditioner; use a load calculation for that.
  • A ton of refrigeration is not a weight.

Guide

Tons of refrigeration to BTU per hour and kilowatts

Air conditioners and chillers are sold by capacity, and the capacity is stated in tons in India, the United States and many other markets, in BTU per hour in others and in kilowatts in most of the rest. Someone comparing a 1.5 ton split unit with a 5 kW listing, or a 12,000 BTU window unit, needs a reliable bridge between them. This page converts tons of refrigeration to BTU per hour, kilowatts, watts and horsepower.

The definition

A ton of refrigeration is the rate at which one short ton, 2,000 pounds, of ice at 0 °C melts in 24 hours. With a latent heat of fusion of 144 BTU per pound, that is 288,000 BTU per day, or 12,000 BTU per hour. In SI units this is 3,516.85 watts, so one ton is 3.516853 kW. The page uses 12,000 BTU/h per ton, with the International Table BTU of 1,055.05585 joules.

Using the converter

The page opens on 1.5 tons and shows 18,000 BTU/h. An extra line gives 5.275 kW of cooling, and the list under it shows 5.2752793 kW, 5,275.2793 W and 7.074266 hp. Enter another capacity, swap the direction to start from BTU/h, or choose another pair. The decimals control sets automatic precision or fixes 2, 4 or 6 places, and the formula line shows the factor.

The table

The table lists 0.5, 1, 1.5, 2, 2.5, 3, 5, 10 and 20 tons in BTU/h: 6,000, 12,000, 18,000, 24,000, 30,000, 36,000, 60,000, 120,000 and 240,000. Every row is the tonnage times 12,000, which is why sizes line up on the familiar steps of 6,000 BTU/h. Convert the same rows to kilowatts by swapping the To unit, for example 2 tons to 7.034 kW.

Cooling capacity versus power draw

The number of tons describes how much heat the machine removes from the air, not how much electricity it uses. A compressor-based system moves several units of heat for each unit of electrical energy, which is what the efficiency ratings express. Because the ratio varies by model, temperature and load, the page does not estimate running cost. It converts the capacity figure on the label, and efficiency must be read separately.

Worked examples

1.5 tons is 18,000 BTU/h and 5.2752793 kW. 2 tons is 24,000 BTU/h and 7.033706 kW. 5 tons is 60,000 BTU/h and 17.584 kW. In the other direction, 12,000 BTU/h is exactly 1 ton, 9,000 BTU/h is 0.75 ton and 5 kW of cooling is 1.4217 tons. A chiller of 20 tons is 240,000 BTU/h, which is 70.34 kW. These come straight from the two definitions.

Choosing a size

Picking the size of an air conditioner depends on the room area, ceiling height, sun exposure, insulation, the number of people and local climate, and a conversion cannot weigh these. Sellers use rules of thumb that differ by country, and sizing that is too small will run continuously while one that is too large cycles often and dehumidifies poorly. Ask a qualified installer for a heat-load calculation when the choice matters.

Limits

The page converts a rated capacity from one unit to another. It does not account for the outdoor temperature at which the rating was taken, for the difference between sensible and latent cooling or for the heating capacity of a heat pump. Real units list their rating under a stated test condition, and the delivered cooling on a very hot day is lower than the nameplate. For heating loads in BTU/h, the same conversion applies.

Checked against the current version of the Tons of Refrigeration to BTU/h on .

Frequently asked questions

Does a 1.5 ton air conditioner weigh 1.5 tons?

No. The ton here is a rate of heat removal, not a mass. It comes from the cooling effect of melting one short ton of ice over 24 hours, which is 12,000 BTU/h or 3.517 kW. A 1.5 ton unit removes 18,000 BTU of heat per hour, and the machine itself weighs perhaps tens of kilograms.

Is cooling capacity the same as the electricity an AC uses?

No. Capacity is heat moved out of the room, and the compressor needs much less electrical power than that. The ratio is the energy efficiency ratio, EER, in BTU/h per watt. For illustration, an 18,000 BTU/h unit with an EER of 10 would draw about 1,800 W, and a better one draws less. Read the label for real figures.

How many BTU is a ton of AC?

One ton of refrigeration is 12,000 BTU per hour, which is 3.517 kW of cooling.

How many tons do I need for a room?

It depends on the room, climate, sun and insulation. A common rough rule is about 600 BTU/h per square meter, but use a proper load calculation or a professional.

Keep working with the result

openWorkstand also includes a free workspace with documents, spreadsheets, tasks, projects and a calendar that save to a folder on your computer.