1. Home
  2. Converters
  3. Amps to Watts

Amps to Watts

For students, hobbyists and technicians working out electrical power.

Free, no sign-up. Runs in your browser: nothing is uploaded.

Free workspace included. Docs, spreadsheets, notes and tasks that save on your device. No sign-up.Take a look

How to use Amps to Watts

  1. Type a value and check the two units.
  2. Read the result, the formula and the table.
  3. Copy the number, or swap the direction.

Features

  • DC, single phase and three phase
  • Power factor input
  • Solve for watts, amps or volts
  • kVA shown
  • Large-current warning

Supported formats

Input

  • A typed number

You get

  • On-screen result

Private by design

Everything you enter is processed by your browser on this device. Nothing is sent to openWorkstand or anyone else, so the Amps to Watts is safe for private and work data. After you have used it once while online, it also works without an internet connection. How local processing works

Good to know

  • It is a calculation, not an electrical design: choose breakers and cables from your local wiring rules.
  • It assumes a steady load and a fixed power factor.

Guide

Amps to watts for DC, single-phase and three-phase circuits

An appliance label may give amps and volts but not watts, a plug or a generator may give watts but not amps, and an electrician needs to move between them. The conversion is simple for a battery and slightly more complex for a mains circuit, where the power factor and the number of phases matter. This page calculates watts from amps and volts, and can also solve for the other quantities.

The formulas

For direct current, power in watts is volts times amps. For single-phase alternating current it is volts × amps × power factor. For three-phase it is √3 × line-to-line volts × amps × power factor, where √3 is 1.7321. The power factor ranges from 0 to 1 and is 1 for a purely resistive load. These are the standard relations, and the page shows which one it used in a note under the results.

Using the converter

Choose the Supply, DC, AC single phase or AC three phase, and Work out, Watts, Amps or Volts. Fields for the two known quantities appear, and Power factor appears for AC. The page opens on single phase 10 A at 230 V with a power factor of 1 and gives 2,300 W, 2.3 kW, 10 A, 230 V and 2.3 kVA of apparent power. Sample chips load three cases.

Reading the result rows

Watts is the real power, Kilowatts is the same divided by 1,000, and Amps and Volts repeat the circuit. Apparent power in kVA is volts times amps, or √3 times that for three phase, divided by 1,000. The kVA figure is larger than the kW figure when the power factor is below 1. A generator or transformer is rated in kVA because the current, not the real power, sets its heating.

Worked examples

Single phase, 10 A at 230 V, power factor 1 is 2,300 W. The same current at power factor 0.9 is 2,070 W. A three-phase load of 16 A at 400 V and power factor 0.85 is 9,422.36 W, 9.4224 kW and 11.085 kVA. A 12 V DC circuit with 5 A is 60 W. Solving the other way, 2,300 W at 230 V is 10 A, as the watts-to-amps page confirms.

Which voltage to enter

For three-phase work, enter the voltage between any two lines, which is commonly 400 or 415 V in many countries and 208 or 480 V in others. For single-phase, enter the supply voltage, for instance 230 V or 120 V. If you only know the phase-to-neutral voltage of a three-phase system, multiply it by 1.732 first. The page does not guess which kind you mean, so state it in the Supply field.

Large currents

When the current exceeds 16 A on a DC or single-phase circuit at 250 V or less, the page adds a warning that this is a large current for a household socket circuit. The threshold is a reminder, not a rule, and it does not apply to three-phase supplies. Choose breakers and cables from the local electrical code and a qualified electrician, not from this result.

Limits

The page is an arithmetic tool and not an electrical design. It assumes steady, sinusoidal AC at a single power factor, and it does not model starting currents, harmonics, voltage drop or cable heating. Power factor must be above 0 and not more than 1, and amps, volts and watts must be positive. For household wiring, motors and generators, follow the code and the manufacturer.

Checked against the current version of the Amps to Watts on .

Frequently asked questions

What is the power factor and why does it matter?

It is the share of the current that does useful work, a number from 0 to 1. A heater is 1, while induction motors are typically 0.8 to 0.9, so the same current means fewer real watts. The page multiplies by it for AC supplies and keeps apparent power, in kVA, separate so you can see both figures.

Why does a three-phase calculation use the square root of three?

Because the voltage between two lines of a three-phase supply is 1.732 times the voltage from a line to neutral, and the three phases each carry current. The page uses the line-to-line voltage, such as 400 V, so power is 1.7321 × 400 × 16 × 0.85 for the sample. Do not enter the phase-to-neutral voltage here.

How do I convert amps to watts?

Multiply by the voltage: watts = volts × amps for DC. For AC, also multiply by the power factor, and by √3 for three phase at the line voltage.

What is power factor?

The ratio of real power to apparent power. It is 1 for a heater and typically 0.8 to 0.9 for motors, which draw more current than their real power suggests.

Keep working with the result

openWorkstand also includes a free workspace with documents, spreadsheets, tasks, projects and a calendar that save to a folder on your computer.