Serial Dilution Calculator

For microbiology, assays and standard curves: exactly what to pipette into each tube and which well holds which concentration.

Free, no sign-up. Runs in your browser: nothing is uploaded.

Free workspace included. Docs, spreadsheets, notes and tasks that save on your device. No sign-up.Take a look

How to use Serial Dilution Calculator

  1. Enter your numbers, or press a sample to see an example.
  2. Read the results and the table under them.
  3. Copy the results or download the table as a CSV file.

Features

  • Any dilution factor from 10-fold to half-log to 2-fold
  • Transfer and diluent volume for every tube
  • Concentration and cumulative dilution per tube
  • A plate layout with 1 to 8 replicate rows and a blank column
  • Up to 12 tubes

Supported formats

Input

  • Typed numbers

You get

  • On-screen tables
  • CSV tables
  • Chart (SVG and PNG)

Private by design

Everything you enter is processed by your browser on this device. Nothing is sent to openWorkstand or anyone else, so the Serial Dilution Calculator is safe for private and work data. After you have used it once while online, it also works without an internet connection. How local processing works

Good to know

  • It is a calculation aid, not a laboratory protocol: follow your lab’s procedures and the manufacturer’s instructions.
  • It assumes ideal mixing and accurate pipetting.

Guide

Serial dilutions: volumes, concentrations in every tube and a 96-well plate layout

In a serial dilution you dilute a sample step by step, each tube made from the last, so that the concentration falls by the same factor each time. It is the standard way to reach a very low concentration from a stock without pipetting tiny volumes, to count bacteria that are too crowded to count directly, to make a standard curve and to measure titers and dose responses. This calculator plans the series: the volumes for each tube, the concentrations and where each tube sits on a plate.

How the series works

Choose a dilution factor f and a final volume V for every tube. You take V/f from the previous tube, add V − V/f of diluent and mix, so the concentration is multiplied by 1/f. After n tubes the concentration is C₀ / fⁿ, and the total dilution is fⁿ. For a ten-fold series in 1,000 µL tubes, the transfer is 100 µL and the diluent 900 µL. The same transfer volume is used at every step, which makes the series easy to run.

Using the calculator

Enter the starting concentration and its unit, the dilution factor, the number of tubes (1 to 12), the final volume in µL, the number of replicate rows on a plate (1 to 8) and whether to add a diluent-only control column. The page opens on 1000 µg/mL, a factor of 10, six tubes of 1,000 µL, three replicates and a control: a 100 µL transfer, 900 µL of diluent, a total dilution of 1 : 1,000,000 and a lowest concentration of 0.001 µg/mL, using 5,400 µL of diluent in all.

The tubes table

For each tube the table lists the concentration, the cumulative dilution, the transfer volume and the diluent volume: tube 1 is 100 µg/mL (1 : 10), tube 2 is 10 µg/mL (1 : 100) and so on to 0.001 µg/mL (1 : 1,000,000) for tube 6. The first tube is made from the stock, which therefore needs 100 µL, and every later tube takes 100 µL from the one before. The chart shows the logarithm of the concentration falling in a straight line, as it should.

The plate layout

The second table lays the series out on a microplate: one tube per column, with the replicates down the rows A to H, so three replicates occupy rows A to C. With the control option on, the next column holds diluent only, which gives the blank. The default plan uses columns 1 to 7 of rows A to C and labels the wells A1 to C7; the concentration row above them tells you what each column holds. Rows of a single replicate are named row A.

Worked plans

A two-fold series of 11 tubes starting at 100 nM in 100 µL tubes uses a 50 µL transfer and 50 µL of diluent, giving 50, 25, 12.5, 6.25, 3.125, 1.5625 nM and on down to 0.048828125 nM, a 1 : 2,048 dilution; with four replicates and a blank it fills 12 columns of rows A to D. Bacterial plating from 900 µL tubes needs 90 µL transfers and 810 µL of diluent for 10⁻¹ to 10⁻⁶. Half-log steps of 3.1623 in 200 µL tubes need 63.245106 µL and 136.75489 µL.

Good technique

Mix each tube thoroughly before transferring, use a fresh tip for each transfer, and keep transfer volumes at or above about 5 µL so that pipetting error stays small. Errors accumulate down a series, since each tube inherits the error of the previous one, so for critical work prepare the standards independently from the stock. If a transfer volume is too small to be practical, use a bigger final volume or fewer tubes with a larger factor.

Limits

The calculator assumes ideal mixing, accurate pipetting and that volumes are additive. It does not know your assay, your pipettes’ accuracy or how much you need in each well, and it limits the series to 12 tubes and the plate to rows A to H. It plans a plate of 8 rows by 12 columns (96 wells) only. Follow your laboratory’s protocol and safety rules; this is an arithmetic aid.

Checked against the current version of the Serial Dilution Calculator on .

Frequently asked questions

How do I read the total dilution factor?

It is the product of all the steps: a ten-fold series of six tubes is 10⁶, written 1 : 1,000,000, so the last tube holds one millionth of the starting concentration. For the plating example with 10⁻¹ to 10⁻⁶ it means counting colonies in a tube diluted a million times and multiplying the count back up to estimate the original number of cells.

Why would I choose a two-fold or half-log series instead of ten-fold?

Because they sample concentrations more finely. A ten-fold step jumps a whole order of magnitude, which suits counts that span many orders, such as bacteria. A two-fold series gives 12 points across a 2,048-fold range for dose-response curves and titers, and half-log steps of about 3.16 give two points per ten-fold range, a common compromise for standard curves.

How do I make a ten-fold series in 1 mL tubes?

Put 900 µL of diluent in each tube, transfer 100 µL from the previous tube and mix. The tool lists the volumes and concentrations for any factor.

Why does error grow along a serial dilution?

Each tube inherits the pipetting error of the one before it, so keep transfer volumes above about 5 µL and use fresh tips.