Guide
PCB trace width from current: the IPC-2221 formulas, copper weight and temperature rise
A trace on a printed circuit board is a thin copper conductor, and when it carries current it heats up. Too narrow a trace gets hot enough to damage the board or burn open. The IPC-2221 standard gives a formula for the trace area needed to carry a current with a chosen temperature rise, and most layout tools use it. This calculator evaluates it for you, in millimetres as well as mils.
The equation
IPC-2221, derived from charts in the older MIL-STD-275, says I = k × ΔT^0.44 × A^0.725, where I is the current in amperes, ΔT the rise above ambient in °C, A the cross-section in square mils and k a constant. For external layers k is 0.048 and for internal layers 0.024. Solving for the area gives A = (I / (k × ΔT^0.44))^(1/0.725). Dividing the area by the copper thickness gives the width. The relationship is not linear: doubling the current needs about 2.6 times the area.
Copper weight
Copper thickness on a board is given as the weight of copper per square foot: 1 oz is 1.378 mil, about 35 µm. The tool accepts 0.5, 1, 2 and 3 oz. Thicker copper allows narrower traces for the same current, as the table of widths for the four weights shows. For 2 A at a 10 °C rise on an outer layer, 1 oz needs 0.781 mm but 2 oz needs 0.391 mm.
Outer and inner layers
Outer layers can lose heat to the air, while inner layers are insulated by the laminate, so the formula allows only half the current for the same area on an inner layer. A 1 A trace on an inner layer of 1 oz copper needs the same 0.7814 mm as a 2 A trace on an outer layer. In practice the difference is smaller than the standard suggests, which is one reason designers also check IPC-2152.
Worked examples
A 2 A trace with a 10 °C rise on 1 oz outer copper needs 42.39 mil² of copper, which is 30.76 mil or 0.7814 mm wide. Over 50 mm at a hot-copper temperature of 35 °C the resistance is 33.37 mΩ, the voltage drop is 66.75 mV and the trace dissipates 133 mW. A 5 A power rail on 2 oz copper with a 20 °C rise and a 40 °C ambient needs 35.74 mil, or 0.9079 mm; over 80 mm it drops 125.6 mV and loses 628 mW. The graph plots the current capacity against width for your copper weight and marks your trace.
Resistance and drop
The width fixes the copper area, and the resistance follows from copper’s resistivity at the operating temperature, the ambient plus the rise. Add your trace length and the tool reports resistance, drop and power. Long power traces on thin copper can lose more voltage than the heating limit suggests, so check both.
Limits
IPC-2221 is conservative and rests on dated test data. The newer IPC-2152 accounts for the thermal effect of copper planes, board thickness and airflow and usually permits narrower traces. The tool ignores vias, pads, adjacent heat sources and pulsed currents, and the fabricator’s minimum trace width also applies. For critical designs, test a prototype with a thermal camera.
Related tools
- Wire Gauge Calculator does the same job for cable rather than copper traces.
- Ohm’s Law Calculator links the current and resistance behind the voltage drop.
- LED Resistor Calculator sets currents that traces will carry.