Choosing wire gauge for a car or boat circuit from current, length and voltage drop
A wire has resistance, and every ampere passing through it loses some voltage on the way. On a 230-volt mains circuit a small loss hardly matters. On a 12-volt circuit in a car, a camper or a boat it can be a quarter of the supply, so lights go dim, motors run slowly and inverters shut down. Choosing the gauge for the distance is therefore an essential first step, and this calculator does it from the current, the length and the voltage drop you can tolerate.
How it works
The tool finds the current, either as amps or as watts divided by the system voltage. It works out the length of wire in the circuit, doubling the one-way distance when the return path is a wire of the same size. The largest drop allowed is the system voltage times the percentage. The smallest conductor area is then the resistivity of copper times the path length times the current, divided by the allowed drop. The resistivity is corrected for the temperature you enter, because copper conducts worse when hot.
Choosing the drop
A 3 percent drop (0.36 V at 12 V) is a common target for lights and electronics. Motors can often accept 10 percent when they start, though they then run hotter. Charging circuits are the most sensitive: a small drop in a battery charging cable means the battery is not fully charged. Change the percentage to see how a looser limit allows a thinner wire.
A worked example
Press the first sample: a 30 amp load 5 metres from a 12 V source. The wire runs out and back, so the path is 10 metres, and the allowed drop is 0.36 V. The smallest conductor is 15.5 mm², so the smallest standard wire is 4 AWG, with an area of 21.15 mm². At that size the resistance is 8.792 mΩ, the drop is 0.264 V (2.2 percent) and the wire wastes 7.91 W as heat. The second sample is a 1,200 W inverter at 12 V: 100 A over 4 metres of wire with a 2 percent limit needs 30.99 mm², so 2 AWG. The third, 10 A of trailer lights over 7 metres with a 5 percent limit, needs only 4.339 mm², which is 10 AWG.
The table of nearby sizes
Under the answer a table lists the sizes either side of the one chosen, with the area, the resistance, the drop in volts and percent, and the power lost as heat. It lets you see what the next size up buys: for the 30 A circuit, going from 4 AWG to 2 AWG lowers the drop from 2.2 to about 1.4 percent. For a battery charging cable or a long run, the extra copper is usually worth it.
What is not checked
Voltage drop is only one limit. The wire must also carry the current without overheating, which depends on the insulation rating, the number of wires in a bundle and the temperature around them, and it must be protected by a fuse or breaker that trips before the wire is damaged. The tool does not choose the fuse or check the insulation, and it assumes copper wire; aluminium has more resistance. Use a table for the insulation you are using, and follow the equipment instructions.
Limits
The calculation uses the wire temperature you enter, and a hot engine bay raises resistance. Connectors, crimps and corroded terminals each add resistance that the calculation ignores, so leave a margin. For critical circuits, such as starter motor cables, use the figure the manufacturer gives.
Related tools
- Wire Gauge Calculator converts between AWG sizes, diameters and areas.
- Battery Life Calculator finds how long a battery runs a given current.
- RV Solar Calculator sizes the panels and battery for an off-grid system.
- Electricity Cost Calculator prices the energy a device uses.
Checked against the current version of the Automotive Wire Size Calculator on .