Sizing an air conditioner: BTU per hour, tons and kilowatts for a room
Buying an air conditioner for a room starts with its capacity, written in BTU per hour (British thermal units), in tons or in kilowatts. A full load calculation of a building involves insulation, windows, orientation and climate, but for a single room a simple sizing guide gives a sensible answer. This calculator uses the Energy Star room-size guide for the base figure and applies common adjustments.
The base size
The Energy Star guide gives the cooling capacity for a room by floor area: 5,000 BTU/h for rooms up to 150 ft² (14 m²), 6,000 up to 250 ft², 7,000 up to 300, 8,000 up to 350, 9,000 up to 400, 10,000 up to 450, 12,000 up to 550, 14,000 up to 700, 18,000 up to 1,000, 21,000 up to 1,200, 23,000 up to 1,400, 24,000 up to 1,500, 30,000 up to 2,000 and 34,000 up to 2,500. The page shows the whole table. Enter the floor area in square metres or square feet.
The adjustments
The base figure assumes an 8 ft ceiling, normal sun and two people. The tool scales it by the ceiling height divided by 8 ft, takes off 10% for a heavily shaded room, adds 10% for a very sunny one with large sun-facing windows, adds 600 BTU/h for each person beyond two and 4,000 BTU/h for a kitchen, where the oven and cooker add heat. These adjustments are the rules in the Energy Star guidance, apart from the height scaling, which is a proportional correction for the volume of the room.
BTU, tons and kilowatts
One BTU per hour is 0.2931 W, so 12,000 BTU/h, a ton of cooling, is 3.517 kW. The page gives the load in all three units and the nearest standard size above it, from the usual sizes of 5,000, 6,000, 8,000, 10,000, 12,000, 14,000, 15,000, 18,000, 24,000, 30,000 BTU/h and larger. A load of 6,890 BTU/h is best served by an 8,000 BTU/h unit.
A bedroom
A bedroom of 25 m² is 269 ft², which falls in the 300 ft² band with a base of 7,000 BTU/h. With a 2.4 m (7.87 ft) ceiling and two people the load is 7,000 × 0.984 = 6,890 BTU/h, which is 0.574 tons or 2.02 kW. The next size is 8,000 BTU/h. If the room has a large west window, choose the very sunny option, which raises the load to 7,580 and still points to an 8,000 BTU/h unit.
A sunny living room and a kitchen
A living room of 400 ft² with a 9 ft ceiling, very sunny and four people starts at 9,000, becomes 10,125 for the height, 11,138 for the sun and 12,338 with two extra people, which needs a 14,000 BTU/h unit (1.17 tons). A 15 m² kitchen has a base of 6,000 BTU/h, 5,906 for the ceiling and 9,906 with the 4,000 BTU/h kitchen allowance, so a 10,000 BTU/h unit is right.
Why a good fit matters
A well-sized unit runs for long enough to remove the moisture as well as the heat. An oversized one switches off too soon, while an undersized one never reaches the set temperature on the hottest days. Inverter units can vary their output and tolerate a larger size better. Doors that open into another room, poor insulation and a top-floor flat under the roof raise the load.
Limits
This is a rule-of-thumb sizing guide for one room, not a Manual J load calculation. It does not account for insulation, window area and glazing, local climate, heat from equipment or adjoining rooms, and it does not choose between unit types. For a whole house or a commercial space, ask a contractor for a proper calculation.
Related tools
- Tons to BTU Converter converts between tons and BTU per hour directly.
- Watts to Horsepower converts power ratings when comparing machines.
- Electricity Cost Calculator estimates what the unit costs to run.
- Area Converter converts room areas between square metres and square feet.
Checked against the current version of the AC BTU Calculator on .