Guide
Pressure drop in a pipe: Darcy-Weisbach, Reynolds number, friction factor and fittings
Water through a pipe loses pressure to friction, and the longer, narrower and rougher the pipe, or the faster the flow, the more it loses. Knowing how much matters for irrigation lines, workshop air and water, heating loops and anything fed by a pump or a tank. This calculator uses the standard Darcy-Weisbach method to give the velocity, the flow regime and the pressure drop for water or another liquid.
The method
Friction in a straight pipe follows the Darcy-Weisbach equation: the pressure drop is f × (L ÷ D) × ρ × v² ÷ 2, where f is the friction factor, L the length, D the inside diameter, ρ the density and v the mean velocity. Fittings are added as a coefficient K times the same dynamic pressure, ρv² ÷ 2, so the total is (f × L ÷ D + ΣK) × ρv² ÷ 2. The head loss is that pressure divided by ρ times gravity, which gives metres of the liquid.
The friction factor
For laminar flow, with a Reynolds number below 2,300, f is exactly 64 divided by Re. For turbulent flow it depends on the relative roughness, the pipe’s roughness height divided by its diameter, and on Re through the Colebrook-White equation, which the tool solves by iteration starting from the Swamee-Jain approximation. The roughness values are typical for new pipe: 0.0015 mm for plastic and drawn copper, 0.045 mm for commercial steel, 0.15 mm for galvanised iron, 0.26 mm for cast iron and about 1 mm for concrete.
Fluid properties
For water the page interpolates density and kinematic viscosity from a table at 0, 5, 10, 20, 30, 40, 60, 80 and 100 °C: at 20 °C they are 998.21 kg/m³ and 1.004 × 10⁻⁶ m²/s. For another liquid enter the density and the dynamic viscosity in millipascal-seconds (centipoise); the kinematic viscosity is the viscosity divided by the density. Cold water is more viscous, so it has a lower Reynolds number and a somewhat different friction factor.
A worked example
Two litres per second of 20 °C water pass through 100 m of 50 mm commercial steel pipe with fittings totalling K = 3. The velocity is 1.019 m/s, the Reynolds number is 50,727 and the flow is turbulent with f = 0.0237. The pressure drop is 26.09 kPa, which is 3.785 psi and 0.261 bar, equal to 2.666 m of head. A garden-hose line of 20 L/min through 30 m of 19 mm plastic pipe at 15 °C with K = 2 runs at 1.176 m/s and loses 30.02 kPa.
Laminar flow and a height change
Viscous oils are different. A 40 mPa·s oil flowing at 1 L/s through 40 m of 1 inch steel pipe moves at 1.974 m/s but has a Reynolds number of only 1,065, so it is laminar with f = 64 ÷ Re = 0.06008, and the drop is 163.2 kPa. If the pipe also rises 2 m, the pump must add ρ × g × 2 m, and the page shows 179.9 kPa as the total pressure needed.
Limits
The pipe is assumed full, straight and carrying a steady flow of an incompressible liquid. The tool does not select a pump, model partly full pipes, open channels, two-phase flow or gases with large pressure changes, nor account for ageing and scaling that roughen a pipe over years. It also treats the entered diameter as the true inside diameter, which for plastic and steel pipe is smaller than the nominal size.
Related tools
- Volume Calculator converts the capacity of tanks and pipe runs into litres.
- Beam Deflection Calculator checks the supports that carry a heavy pipe.
- Pool Volume Calculator sizes the water volume that a pump has to turn over.
- Speed Converter converts the velocity into other units.
Checked against the current version of the Pipe Flow Calculator on .