Guide
Lumens to lux: how bright a lamp is over an area
Lamps are sold in lumens, but rooms and work surfaces are judged in lux. A box says 800 lumens, a guide says an office desk should have 300 to 500 lux, and a buyer has to link the two. The link is the area the light covers. This page gives illuminance from lumens and an area, or from lumens and the geometry of a spotlight, and shows the answer in lux and foot-candles.
The definitions
A lumen is the unit of luminous flux, the total light a source emits as the eye sees it. A lux is one lumen per square meter of surface, and a foot-candle is one lumen per square foot. Since a square meter is 10.7639 square feet, 1 foot-candle is 10.7639 lux. For an even spread, lux = lumens ÷ area in square meters. The page reports ‘Illuminance’, ‘Foot-candles’ and ‘Area lit’.
Area mode
Under I know, choose The area lit (m²), then enter the Luminous flux in lumens and the Area. The page opens on 800 lumens over 4 m² and shows 200 lux, 18.58 foot-candles and an area of 4 m². The same lamp over 10 m² gives 80 lux, and 1,200 lumens over 12 m² gives 100 lux. The calculation treats the flux as spread evenly over the whole area.
Spotlight mode
Choose The distance and beam angle to model a spot. The lit circle has a radius of distance × tan(angle ÷ 2), and its area is π times the radius squared. For 600 lumens at 2.5 m with a 60° beam, the radius is 1.443 m, the area is 6.545 m² and the illuminance is 91.67 lux, 8.52 foot-candles. A narrower beam concentrates the light, and doubling the distance quadruples the area.
Typical levels
The page’s hint mentions 100 to 200 lux for living rooms and 300 to 500 lux for offices. Those are guides, not rules, and recommended levels differ by task, age and local standard. To light 20 m² of office to 500 lux you would need about 10,000 lumens reaching the surface, and more from the lamps once losses are counted. The page calculates and does not choose fittings.
Worked examples
800 lumens over 4 m² is 200 lux and 18.58 foot-candles. 800 lumens over 10 m² is 80 lux. A spot of 600 lumens at 2.5 m with a 60° beam lights 6.545 m² at 91.67 lux. For an office of 20 m² at 500 lux, 10,000 lumens must land on the surface. In the other direction, 100 lux over 12 m² needs 1,200 lumens. These follow from the formula in the paragraph above.
Losses in a real room
Light from a lamp is absorbed by shades, reflected from walls and ceilings, and falls off with distance. Designers apply a utilisation factor to the lumens, and a maintenance factor for dirt and ageing. The page’s note suggests a range of about 0.5 to 0.8 for the first. If the lamp’s lumen rating is for the bare bulb in a shade, the light reaching the desk is lower than the rating, so use the calculation as an upper limit.
Limits
The result is an average over the area, not the value at a point. The centre of a spotlight is brighter than its edge, and a lamp’s beam rarely has a sharp boundary. The page does not account for colour, reflectance, glare or the distribution of a fitting, and it does not convert between lumens and watts, which depends on the efficiency of the lamp. For a lighting design, use the fitting’s photometric data.
Related tools
- Square Meters to Square Feet converts the room area.
- Watts to Amps finds the current a bank of lamps draws.
- Meters to Feet converts the distance to the surface.
- Wh to mAh sizes the battery behind a portable lamp.