Guide
Converting kinematic viscosity between centistokes, mm²/s, stokes and m²/s
Kinematic viscosity is how fast a fluid flows under its own weight. It equals the dynamic viscosity divided by the density, which is why a heavy and a light fluid of the same dynamic viscosity pour differently. It is the number on lubricating oil data sheets and in hydraulic fluid grades. This page converts among eight kinematic viscosity units and shows what the value means as a dynamic viscosity.
The units
In SI the unit is a square metre per second, because viscosity divided by density leaves length squared over time. That is inconvenient for oils, so the older centimetre-gram-second unit, the stokes, with its hundredth, the centistokes, is still the working unit: one stokes is a square centimetre per second, 10 to the minus 4 m²/s, and one centistokes is one square millimetre per second. Because of that, a viscosity in centistokes and in mm²/s is the same number. Square feet per second, square feet per hour and square inches per second complete the list for US sources.
Using the converter
Choose the units, type a value and read the result with the formula. The swap button reverses them, and the page lists all eight units for the same viscosity. A line gives the dynamic viscosity that goes with this kinematic value if the fluid has a density of 1,000 kilograms per cubic metre, like water; for other densities multiply by the density in kilograms per cubic metre divided by 1,000. The reference table runs through 1, 5, 10, 32, 46, 68, 100, 220 and 460 of the starting unit.
Oil grades
The ISO viscosity grades, such as VG 32, VG 46 and VG 68, name the kinematic viscosity at 40 degrees Celsius in centistokes, with a tolerance of plus or minus 10 percent. Hydraulic oils are commonly sold in VG 32, 46 and 68, and gear oils in VG 100 up to 460 and beyond. Several of those numbers sit in the reference table, which makes it easy to see them in SI terms: VG 46 is 0.000046 m²/s. The grades are tied to a temperature, and viscosity falls sharply as oil warms.
Edge cases
Zero and negative values convert but are not physical. The kinematic viscosity of water at 20 degrees is about 1 cSt, and of air at room temperature about 15 cSt, so the same scale spans gases and thick oils. The page does not convert the Saybolt, Redwood or Engler scales, which are time-based and depend on the instrument, and which have approximate tables rather than exact factors.
A worked example
The default conversion is 10 centistokes to square metres per second, which gives 0.00001. At a density of 1,000 kg/m³ the corresponding dynamic viscosity is 0.01 Pa·s. The table gives 1 cSt as 0.000001 m²/s, 5 cSt as 0.000005, 32 as 0.000032, 46 as 0.000046 and 68 as 0.000068. One stokes is 100 centistokes, and one square foot per second is 92,903.04 centistokes.
Limits
The conversion gives the number in another unit and nothing about a particular fluid, its temperature or its suitability for a machine. Check the manufacturer’s recommended grade. Empirical scales such as Saybolt universal seconds are outside the scope of an exact unit converter.
Related tools
- Dynamic Viscosity Converter works with the viscosity before dividing by density.
- Unit Converter handles areas and times separately when that is simpler.
- Pipe Flow Calculator uses the viscosity of a fluid in flow calculations.
- Area Converter converts the square-metre and square-foot parts of these units.
Checked against the current version of the Kinematic Viscosity Converter on .