1. Home
  2. Calculators
  3. Activation Energy Calculator

Activation Energy Calculator

For kinetics homework and lab data: how strongly the rate of a reaction depends on temperature.

Free, no sign-up. Runs in your browser: nothing is uploaded.

Free workspace included. Docs, spreadsheets, notes and tasks that save on your device. No sign-up.Take a look

How to use Activation Energy Calculator

  1. Enter your numbers, or press a sample to see an example.
  2. Read the results and the table under them.
  3. Copy the results or download the table as a CSV file.

Features

  • Ea from two rate constants and temperatures
  • Rate constant at a new temperature from Ea
  • k from A and Ea
  • kJ/mol, J/mol or kcal/mol and K or °C
  • An Arrhenius plot and the Q₁₀ factor

Supported formats

Input

  • Typed numbers

You get

  • On-screen results
  • Arrhenius plot (SVG and PNG)

Private by design

Everything you enter is processed by your browser on this device. Nothing is sent to openWorkstand or anyone else, so the Activation Energy Calculator is safe for private and work data. After you have used it once while online, it also works without an internet connection. How local processing works

Good to know

  • Two points give one estimate; a fit over several temperatures is better.
  • The simple Arrhenius law assumes one rate-determining step.

Guide

Activation energy and the Arrhenius equation: how reaction rates depend on temperature

Chemical reactions speed up when you heat them, often dramatically. The Arrhenius equation, proposed by Svante Arrhenius in 1889, describes how: the rate constant depends on temperature through an exponential involving the activation energy, the minimum energy that colliding molecules need for a reaction to occur. This calculator finds the activation energy from rate constants at two temperatures, or, given the activation energy, predicts the rate constant at another temperature.

The equation

The rate constant is k = A · e^(−Ea / RT), where A is the pre-exponential factor (related to collision frequency and orientation), Ea the activation energy, R the gas constant 8.314462618 J/(mol·K) and T the absolute temperature. The factor e^(−Ea/RT) is the fraction of molecule pairs with enough energy. Dividing the equation at two temperatures cancels A: ln(k₂/k₁) = (Ea/R)(1/T₁ − 1/T₂), which is the form used here.

Three modes

Under I know, choose Rate constants at two temperatures (find Ea), Ea, and k at one temperature (find k at another) or A and Ea (find k). Set the temperature unit (K or °C) and the activation energy unit (kJ/mol, J/mol or kcal/mol). Rate constants are typed as numbers, with scientific notation allowed, such as 2.5e-3, and may be in any unit of a rate constant as long as both match. Temperatures must be above absolute zero.

Worked examples

If a rate constant of 0.0010 doubles to 0.0020 when the temperature goes from 300 K to 310 K, the activation energy is 53.597261 kJ/mol, which is 53,597.261 J/mol or 12.810053 kcal/mol, and A = k·e^(Ea/RT) = 2,147,480 in the units of k. Using Ea = 53.6 kJ/mol the rate constant at 350 K is 0.021537782, 21.54 times the value at 300 K. With an activation energy of 12 kcal/mol (50.208 kJ/mol) and k₁ = 0.0010 at 300 K, the rate constant at 320 K is 0.0035185495.

A and Ea directly

In the third mode you give A and Ea and the temperature. For A = 1 × 10¹³, Ea = 75 kJ/mol at 25 °C (298.15 K), the rate constant is 0.72538484 in the units of A, and the fraction of molecules with enough energy, e^(−Ea/RT), is 7.2538484 × 10⁻¹⁴. The tiny fraction shows how few collisions are productive, and how sensitive it is to temperature: raising the temperature only slightly increases it by large factors.

The Q₁₀ value

For biological and chemical reactions, the effect of a 10 K rise is often quoted as Q₁₀, the ratio of rate constants 10 K apart. The tool shows it near T₁: 2 for the doubling example, 2.00007 for Ea = 53.6 kJ/mol at 300 K and 1.91423 for 12 kcal/mol (50.208 kJ/mol) near 300 K. It is not a constant: for the same activation energy it falls as the temperature rises. The idea that rates double every 10 K is a rough rule for typical Ea values near room temperature.

The Arrhenius plot

The chart plots ln k against 1000/T with the straight line implied by your two points, marked with a dot at each. A line with a steeper slope means a larger Ea. In a real study you would measure k at five or more temperatures, check that the points fall on a straight line and fit the slope; curvature signals a change in mechanism, tunnelling or a temperature-dependent A. Two points give one estimate and no check.

Limits

The simple equation assumes a single rate-determining step and an activation energy that does not change with temperature, which holds over modest ranges. The tool does not fit more than two points or compute uncertainties, and it does not handle the modified Arrhenius equation with a temperature-dependent prefactor, enzyme denaturation at high temperature or diffusion-limited reactions. The numbers are arithmetic, not a prediction for a particular reaction.

Checked against the current version of the Activation Energy Calculator on .

Frequently asked questions

Is it true that reaction rates double for every 10 °C rise?

Only roughly, and only for certain activation energies and temperature ranges. The factor, called Q₁₀, depends on Ea and on the temperature: the tool shows it near T₁. With Ea = 53.6 kJ/mol at 300 K it is about 2.0, but for Ea = 50.2 kJ/mol near 300 K it comes to 1.91. Reactions with higher Ea respond more strongly to temperature, and low-Ea reactions barely do.

Why do I plot ln k against 1/T?

Taking logarithms of the Arrhenius equation gives ln k = ln A − (Ea/R)(1/T), the equation of a straight line in 1/T with slope −Ea/R. Measuring k at several temperatures and drawing this plot lets you read the activation energy from the slope. The page draws the line through your two points, with 1000/T on the horizontal axis so the numbers are of convenient size.

What is a typical activation energy?

Many reactions fall between 40 and 100 kJ/mol. A rule of thumb that the rate doubles per 10 K corresponds to roughly 50 kJ/mol near room temperature.

Why use kelvin?

The Arrhenius equation uses absolute temperature. The tool converts °C for you.

Keep working with the result

openWorkstand also includes a free workspace with documents, spreadsheets, tasks, projects and a calendar that save to a folder on your computer.